The GBX2000 is a galvanic isolation barrier selected specifically for use between an Intrinsically safe conventional zone and a zone-monitor.
Every GBX2000 (4 terminals) functions like a "DC current isolator" with reverse polarity protection. The input and output are galvanically isolated from each other.
It is designed for the connection of fire detectors, smoke detectors, temperature sensors, etc. The detector's increased current range and the higher accuracy allow for differentiation between normal operation, fire alarm, lead breakage and short circuit currents in the safe area. In many cases they may also be used for controlling I/P converters. A separate power supply with auxiliary power is not required. Due to the input voltage limiting of 24 V, the maximum voltage output is 21 V.
• The isolation of power loops for the control of positioner, I/P converters etc. A current source is connected to the safe area terminals.
• The isolation of a current signal from fire detectors or similar sensors. In this case, a voltage source can be connected to the safe area terminals. A specific measurement current across a passive sensor can be measured in the safe area with a series resistor (min. 50 ohm). When a voltage supply is used, the measuring resistor can also provide current limitations.
Elektrische Angaben | ||
---|---|---|
Betriebsspannung | 4 to 35 VDC |
Physikalisch | ||
---|---|---|
Abmessungen | 20 x 107 x 115 mm | |
Nettogewicht | ± 100 g | |
Montage | DIN-Hutschiene |
Umweltbedingungen | ||
---|---|---|
Umgebung | Drinnen, IS | |
IP Klassifizierung | IP20 |
Regulativ | ||
---|---|---|
Zertifizierung | CENELEC/ATEX |
Inputs/outputs (not intrinsically safe) | ||
---|---|---|
Current | 0 to 40 mA | |
Power loss | at 40 mA and Uin < 22 V: 700 mW at 40 mA and Uin > 22V: 1.2 W |
Inputs/outputs (intrinsically safe) | ||
---|---|---|
Voltage | for 4 V < Uin < 24 V: >= Uin - (0.37 x current in mA) - 1.0 for Uin > 24 V: = 21 V - (0.36 x current in mA) | |
Short-circuit current | at Uin > 24 V: >= 65 mA | |
Transfer current | <= 40 mA |
Ambient temperature | ||
---|---|---|
-20°C to +60°C |
Group, category, type of protection | ||
---|---|---|
II (1) G D [EEx ia] IIC (-20°C <= Tamb <= 60°C) |
Type of protection [EEx ia] | ||
---|---|---|
Explosion group | IIA IIB IIC | |
External capacitance | 2.9 µF 0.82 µF 0.107 µF | |
External inductance | 33 mH 18 mH 4.3 mH |
290,36 €
677,11 €
672,35 €
1 057,91 €
505,75 €
297,50 €
290,36 €
618,80 €
208,25 €
23,79 €
124,95 €
5,41 €
4,88 €
20,22 €
11,89 €
8,93 €
83,29 €
55,93 €
43,44 €
1,79 €
8,93 €
3,21 €
2,37 €
107,09 €
118,41 €
119,00 €
148,75 €
42,83 €
52,36 €
141,61 €
Zusätzliches Sensorkopfpaar, 5-100m für FD3102 Sensorköpfe: Sender und Empfänger Reichweite 5 bis 120 Meter. konfigurierbar 2-Ader Technik für Sender und Empfänger Automatische Kompensation
Isolatormodul, für 950er und 2000er Serie (inkl. CPD-Gehäuse)Automatische Wiederverbindung nach Störungsende Trennung beim Kurzschlussfall CPD Anerkannt
Feuerwehranzeigetableau als zusätzliche Gegenstelle für Brandmeldeanlagen mit integriertem Mikrocontroller.
Türhaftmagnet, Metall, Wandbefestigung, 490 NFreilaufdiode Verpolungschutz Kraft 490N