The GBX2000 is a galvanic isolation barrier selected specifically for use between an Intrinsically safe conventional zone and a zone-monitor.
Every GBX2000 (4 terminals) functions like a "DC current isolator" with reverse polarity protection. The input and output are galvanically isolated from each other.
It is designed for the connection of fire detectors, smoke detectors, temperature sensors, etc. The detector's increased current range and the higher accuracy allow for differentiation between normal operation, fire alarm, lead breakage and short circuit currents in the safe area. In many cases they may also be used for controlling I/P converters. A separate power supply with auxiliary power is not required. Due to the input voltage limiting of 24 V, the maximum voltage output is 21 V.
• The isolation of power loops for the control of positioner, I/P converters etc. A current source is connected to the safe area terminals.
• The isolation of a current signal from fire detectors or similar sensors. In this case, a voltage source can be connected to the safe area terminals. A specific measurement current across a passive sensor can be measured in the safe area with a series resistor (min. 50 ohm). When a voltage supply is used, the measuring resistor can also provide current limitations.
Elektrische Angaben | ||
---|---|---|
Betriebsspannung | 4 to 35 VDC |
Physikalisch | ||
---|---|---|
Abmessungen | 20 x 107 x 115 mm | |
Nettogewicht | ± 100 g | |
Montage | DIN-Hutschiene |
Umweltbedingungen | ||
---|---|---|
Umgebung | Drinnen, IS | |
IP Klassifizierung | IP20 |
Regulativ | ||
---|---|---|
Zertifizierung | CENELEC/ATEX |
Inputs/outputs (not intrinsically safe) | ||
---|---|---|
Current | 0 to 40 mA | |
Power loss | at 40 mA and Uin < 22 V: 700 mW at 40 mA and Uin > 22V: 1.2 W |
Inputs/outputs (intrinsically safe) | ||
---|---|---|
Voltage | for 4 V < Uin < 24 V: >= Uin - (0.37 x current in mA) - 1.0 for Uin > 24 V: = 21 V - (0.36 x current in mA) | |
Short-circuit current | at Uin > 24 V: >= 65 mA | |
Transfer current | <= 40 mA |
Ambient temperature | ||
---|---|---|
-20°C to +60°C |
Group, category, type of protection | ||
---|---|---|
II (1) G D [EEx ia] IIC (-20°C <= Tamb <= 60°C) |
Type of protection [EEx ia] | ||
---|---|---|
Explosion group | IIA IIB IIC | |
External capacitance | 2.9 µF 0.82 µF 0.107 µF | |
External inductance | 33 mH 18 mH 4.3 mH |
404,60 €
1 011,50 €
1 017,45 €
1 163,32 €
1 395,73 €
818,72 €
471,23 €
380,80 €
618,80 €
208,25 €
30,35 €
184,45 €
7,74 €
4,88 €
23,79 €
12,17 €
11,31 €
107,10 €
78,53 €
60,68 €
1,79 €
8,93 €
3,21 €
2,37 €
107,09 €
118,41 €
119,00 €
148,75 €
42,83 €
77,35 €
Der FD-MB40 Reflektor-Adapter wird in Verbindung mit dem FD-MB20 Montagebügel für die Monatge von vier Prisma-Reflektoren an einer senkrechten Achse verwendet. Reflektor-Adapter 4fach für FD-MB20Einfache Justage 0° bis 45° schwenkbar
Insektenschutzgitter für Melder 700er, 2000er Serie (VPE 10 Stk.)Schutz vor Eindringen von Kleinsttieren in die Messkammer kompatibel mit Serie 700 kompatibel mit Serie 2000
Erweiterungsrohr für FDD710Verwendbar mit dem FDD710 Luftschachtmelder Extra lang für große Luftschächte Einfache Installation